Competitor Search Guided Search
click here to chat with us
RG60U

RG60U

RG60U Series

Minarik Drives’ full-featured RG60U regen drive remarkably fits in the industry standard “MM” footprint. Mounted on a gold extruded chassis, the RG60U is ideal for high duty-cycle applications. 
Enable and Inhibit terminals are standard on the RG60U, along with the option to invert their functions. The invert jumpers let the customer decide whether the drive runs or stops when terminals are opened or closed. The eight combinations to choose from provide tremendous application flexibility.
The new robust design of the RG60U enables it to withstand a 1G vibration test, making it an excellent choice for demanding applications!
$272.00
Model
Number
Enclosure Maximum
Current
(ADC)
Input
Voltage
(VAC)
Output
Voltage
(VDC)
Power Range Field / Shunt
Supply
Reversing Isolation
HP kW
RG60U Chassis 10* 115 0 - 90 1/8 - 1 .10 - .75 No Yes No
230 0 - 90 1/8 - 1 .10 - .75
0 - 180 1/4 - 2 .20 - 1.5

*Heat sink kit 223-0159 must be used when the continuous output current is above 5 amps.

  • MM footprint: Extremely compact size with an industry standard mounting footprint.
  • 4Q reversing: Regenerative/4 quadrant drives have the ability to perform quick, contactorless, reversing on-the-fly
  • Speed range and regulation: 1% regulation over 50:1 speed range. 0.1% over 60:1 speed range with the addition of a tachometer for feedback.
  • User adjustable calibration pots: IR compensation, max speed, min speed, forward acceleration, reverse acceleration, forward torque, reverse torque, tachometer and deadband.
  • Diagnostic LEDs: Power, forward current limit, reverse current limit
  • Stopping modes: The user can decelerate (N.O.), regeneratively brake (N.O.) or coast the motor to a stop (N.O. and N.C.).
  • Spade terminals and cage clamp terminal block: Quick and easy wire connections
  • Configurable enable and inhibit: Can be configured to be either normally open or normally closed
  • Additional features: Tachometer feedback, gold extruded chassis and plastic capped trimmer pots
  • PCM option: Add a –PCM to the end of the part number to receive the drive with an isolation daughter card for receiving non-isolated speed reference voltages between –10V and +10V
Introduction to the RGM Series
RGM400 Series Wiring (Line, Motor, Speed Pot)
RGM400 Series Wiring (Alternate Speed Pot Configurations)
Trim Pot Calibration: Minimum Speed
Trim Pot Calibration: Maximum Speed
Trim Pot Calibration: Acceleration
Trim Pot Calibration: Current Limit
Trim Pot Calibration: IR Compensation
Trim Pot Calibration: Deadband
Trim Pot Calibration: Tach Feedback