NEMA 4X Enclosure: Aluminum enclosure rated for protection from dirt and water
UL 61800-5-1 Listed: Tested to the latest UL standard
Microprocessor Based: Allows custom programming for OEMs
Doubler Mode: Will run 230 VAC motors with a 115 VAC line
Selectable Switching Frequency: Can be set to 800, 2k, 8k, or 12k Hz for either audibly quieter motor operation or to prevent GFI tripping.
Adjustable Base Frequency: Can be set for 50 or 60 Hz at rated output voltage, regardless of input frequency
2X RPM: Output can be set to double the rated frequency for higher speed / less torque operation.
Torque Foldback: Allows up to 200% torque for short periods to overcome intermittent peak loads, then reduces the torque to a (preset) safe level
Motor Overload Protection: Separate setting to trip in motor overload condition
Thermally Protects: Drive recognizes when overheated as a result from overload. After flashing a warning code, it will trip if condition persists
Automatic Restart: Can be set for automatic restart after certain fault conditions
DC Injection Braking: Can be used for quicker braking
Diagnostic LEDs: Power, Stop, Status
User Adjustable Calibration Trim Pots: Minimum Speed, Maximum Speed, Torque Limit, Boost, Motor Overload Protection, Slip Compensation, Acceleration, Deceleration, Brake Voltage, Brake Time-out