Competitor Search
click here to chat with us
VFDA4X04-D230-PCM

VFDA4X04-D230-PCM AC Motor Control

Obsolete

  • Compact size: Chassis unit is small and easy to mount.
  • Isolated input: Accepts floating or grounded signals 0-10VDC, 0-5VDC or 4-20mA.
  • DC injection braking: Jumper selectable with adjustable brake current and brake time settings.
  • Output Voltage Doubler: Enables VFD to provide 230V three phase out to the motor when only 115VAC single Phase power supply is available.
  • Torque fold-back feature: Allows up to 200% torque to overcome intermittent peak loads then reduces the torque to the current limit level.
  • Auto or manual restart: Jumper selectable. After a low input voltage fault the VFD will restart itself when minimum input voltage is re-established.
  • Enable and direction inputs: Conveniently interface to the VFD for enable (Start/Stop) and direction (FWD/REV) control.
  • Adjustable 4 to 16kHz switching frequency: Higher frequencies result in audibly quieter motor operation. Lower frequencies produce less electrical noise. Choose the right setting for the environment.
  • User adjustable calibration pots: Minimum speed, maximum speed, current limit, acceleration, deceleration, slip compensation, boost, zero set, brake current and brake time.
  • Diagnostic LEDs: Power, Fault, Enable and Torque Limit.
  • AC line fusing: Conveniently included.


OBSOLETE: Recommended replacement - P4XMDVF04-D230-PCM

Contact the factory for volume pricing

Model
Number
Enclosure Maximum
Current
(ADC)
Input
Voltage
(VAC)
Output
Voltage
(VAC)
Power Range Braking Reversing Isolation
HP kW
VFDA4X05-D230-PCM NEMA 4X 4 115 / 230 - 1Ø 230 - 1Ø & 3Ø 3/8 - 1 .28 - .75 Yes
(DC Injection)
Yes 0 - 5 VDC
0 - 10 VDC
4-20 mA

NEMA 4X Enclosure: Aluminum enclosure that protects against dirt and splashing

AC Line Fusing: Conveniently included

Variety of Motors: Permanent Split Capacitor (PSC), Shaded Pole, Synchronous, and 3Ø Induction

Doubler Mode: Will run 230 VAC motors with a 115 VAC line

Torque Foldback: Allows up to 200% torque for short periods to overcome intermittent peak loads, then reduces the torque to a (preset) safe level

Isolated Logic: Accepts floating or grounded 0-5 VDC, 0-10 VDC, or 4-20 mA signals

Selectable Auto/Manual Restart: Use a jumper to select if the drive should automatically restart after a fault condition clears

Adjustable Switching Frequency: Default 16kHz frequency can be changed to 4k, 8k, 10k, or 12k Hz using kit 202-0108. Higher frequencies result in audibly quieter motor operation, but lower frequencies produce less electrical noise and may prevent GFI tripping.

DC Injection Braking: Can be used for quicker braking

Thermally Protects: Drive recognizes when overheated as a result from overload. After flashing a warning code, it will trip if condition persists

Diagnostic LEDs: Power, Enable, Torque Limit, Fault (Undervoltage, Overvoltage, 250% Current Limit Trip)

User Adjustable Calibration Trim Pots: Minimum Speed, Maximum Speed, Offset, Torque Limit, Slip Compensation, Boost, Acceleration, Deceleration, Brake Current, Brake Time