VFD05-D230-PCM

VFD05-D230-PCM AC Motor Control

Legacy

The Volts/Hertz VFD05-D230AC-PCM has all the features of the VFD series with several additional enhancements. They include an isolated front end, minimum speed adjustment potentiometer, DC injection braking,and automatic or manual restarts.

The dual voltage, isolated VFD05-D230AC-PCM inverter can accept a speed reference signal without a separate isolation card. They can be used with a variety of motors including 3-phase induction, single-phase permanent split capacitor (PSC), shaded pole and synchronous motors.

Packed with features, the VFD05-D230AC-PCM series has a “doubling” jumper that can be set to output 230VAC to a motor when only 115VAC power supply is available. A jumper also determines if the VFD is set for automatic or manual restarting.

If automatic restart is selected, the inverter will restart after a low voltage fault or power loss,when the input voltage is restored to a minimum level. Another jumper selectable option is DC injection braking or coast-to-stop. Customizing the brake time and current is easy with adjustable trimmer pots.

The compact VFD05-D230AC-PCM is available to 1.5 HP, and has the features and flexibility expected in a full-featured AC drive.

Potentiometer Kit 202-0113 is included with a purchase of the VFD05-D230-PCM


Not recommended for new applications.
Direct replacement - MDVF05-D230-PCM

Let's Talk About Your Project

$755.27

Contact the factory for volume pricing

Model
Number
Enclosure Maximum
Current
(ADC)
Input
Voltage
(VAC)
Output
Voltage
(VAC)
Power Range Braking Reversing Isolation
HP kW
VFD05-D230-PCM Chassis 5 115 / 230 - 1Ø 230 - 1Ø & 3Ø 3/8 - 1 1/2 .28 - 1.1 Yes
(DC Injection)
Yes 0 - 5 VDC
0 - 10 VDC
4-20 mA

AC Line Fusing: Conveniently included

Variety of Motors: Permanent Split Capacitor (PSC), Shaded Pole, Synchronous, and 3Ø Induction

Doubler Mode: Will run 230 VAC motors with a 115 VAC line

Torque Foldback: Allows up to 200% torque for short periods to overcome intermittent peak loads, then reduces the torque to a (preset) safe level

Isolated Logic: Accepts floating or grounded 0-5 VDC, 0-10 VDC, or 4-20 mA signals

Selectable Auto/Manual Restart: Use a jumper to select if the drive should automatically restart after a fault condition clears

Adjustable Switching Frequency: Default 16kHz frequency can be changed to 4k, 8k, 10k, or 12k Hz using kit 202-0108. Higher frequencies result in audibly quieter motor operation, but lower frequencies produce less electrical noise and may prevent GFI tripping.

DC Injection Braking: Can be used for quicker braking

Thermally Protects: Drive recognizes when overheated as a result from overload. After flashing a warning code, it will trip if condition persists

Diagnostic LEDs: Power, Enable, Torque Limit, Fault (Undervoltage, Overvoltage, 250% Current Limit Trip)

User Adjustable Calibration Trim Pots: Minimum Speed, Maximum Speed, Offset, Torque Limit, Slip Compensation, Boost, Acceleration, Deceleration, Brake Current, Brake Time