- 115 VAC input only: The EC2 is designed to run a 90 VDC motor with a 115 VAC line.
- No Field Supply: The EC2 does not have the F1 & F2 connections for field-wound / shunt-wound motors. PMDC (permanent magnet DC) motors only.
- No CSA: The EC2 is UL Listed, but does not have CSA.
- Inhibit Connection: The EC2 has inhibit, but uses spade terminal connections instead of a Molex connector.
|
Model Number |
Enclosure |
Maximum Current (ADC) |
Input Voltage (VAC) |
Output Voltage (VDC) |
Power Range |
Field / Shunt Supply |
Braking |
Reversing |
Isolation |
HP |
kW |
EC2
|
Chassis |
10* |
115 |
0 - 90 |
1/8 - 1 |
.09 - .75 |
No |
No |
No |
No |
* Heat sink kit 223-0159 must be used when the continuous output current is above 5 amps.
Features
- Low Cost: Designed for cost savings in large quantities for OEMs
- MM Footprint and Compact Size: Traditional MM mounting pattern with smaller footprint uses minimal space
- Stopping Modes: Inhibt (N.O.) for coasting to stop. Can be used for frequent starting and stopping
|
Technical Data
- 1.37 Form Factor
- 1% Base Speed Regulation
- 60:1 Speed Range
|
Trim Pots
- Maximum Speed
- Minimum Speed
- Acceleration / Deceleration
- Current Limit
- IR Compensation
|