click here to chat with us
DC6-36/48-4Q

DC6-36/48-4Q Low Voltage Motor Control

DC-4Q Series

The DC-4Q series are microprocessor based, low voltage PWM drives that are capable of braking and reversing regeneratively. The microprocessor allows for custom programming to fit any OEMs custom needs, sometimes eliminating the need for a PLC and/or sensors. They can even be programmed for use in the field without trimmer potentiometers, creating a simple install and a level of security for OEMs. Some models contain a “sleep mode” which extends battery life, and some contain a Fault LED with a built in flashing code for under voltage, over voltage, current limit, overheat, and short circuit. With features like pre-charge circuits, brake outputs, directionally based inhibits, you’re sure to find a drive to fit your needs.

Let's Talk About Your Project

$190.86

Contact the factory for volume pricing

Model
Number
Enclosure Maximum
Current
(ADC)
Peak
Current
(ADC)*
Input
Voltage
(VDC)
Output
Voltage
(VDC)
Power Range
Continuous (Peak)
Braking Reversing Isolation
HP kW
DC6-36/48-4Q Chassis 3 6 36 0 - 36 1/40 - 1/10 (1/5) .019 - .07 (.15) Yes
(Regenerative)
Yes
(Regenerative)
No
48 0 - 48 1/25 - 1/8 (1/4) .03 - .09 (.19)

* Peak time of 1 minute.

Features

  • Microprocessor Based: Allows custom programming for OEMs
  • 4Q Reversing: Regenerative / 4-Quadrant drives have the ability to perform quick and contactorless braking and/or reversing-on-the-fly
  • Ideal for Battery Powered Equipment: Maintains both set and/or variable speed even as battery voltage declines. Extends total running time of equipment
  • High Efficiency: Outputs up to 95% of the input voltage
  • Wig-Wag Mode: Allows for bidirectional control of the motor with a unidirectional signal
  • Stopping Modes: N.C. forward and reverse inhibits brake to a stop. Can be used for rapid starting and stopping
  • Diagnostic LEDs: Power, Status(Current Limit, Undervoltage, Overvoltage, Overheat Foldback)

Technical Data

  • 1.01 Form Factor
  • 1% Base Speed Regulation
  • 100:01 Speed Range

Trim Pots

  • Forward Maximum Speed
  • Reverse Maximum Speed
  • Minimum Speed
  • Acceleration
  • Deceleration
  • Motor Current Limit
  • Regen Current Limit